Boonton 4500B Peak Power Meter Manuel d'utilisateur Page 184

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 372
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 183
Boonton 4500B RF Peak Power Analyzer
Operation
4-112
Table 4-53. Spcl > Servicing > Time Skew Adj > Submenu
Menu Item Function
(Type) Selections (SCPI cmd)
CH1 Skew Adj 0.0 to ± 99.9 nsec Adjust the time skew of channel 1
(Numeric)
Press the Spcl > Servicing > Time Skew > CH1 Skew Adj menu key to
display a menu to adjust the timing skew between channel 1 and the
trigger system time reference.
CH2 Skew Adj 0.0 to ± 99.9 nsec Adjust the time skew of channel 1
(Numeric)
Press the Spcl > Servicing > Time Skew > CH2 Skew Adj menu key to
display a menu to adjust the timing skew between channel 2 and the
trigger system time reference.
Vue de la page 183
1 2 ... 179 180 181 182 183 184 185 186 187 188 189 ... 371 372

Commentaires sur ces manuels

Pas de commentaire