Boonton 4540 Series RF Power Meter
Operation
4-61
4.5.38 System > I/O Config > Ethernet > Extensions Menu
The Ethernet Extensions menu contains menu items for displaying and editing the IP address, subnet mask, default gateway.
There is also a read-only menu for the MAC address.
Main Pg 2 > System > I/O Config > Ethernet > Extensions > IP Address
Description: Set the Internet Protocol (IP) address of the Ethernet
adapter. Note: If DHCP/AutoIP mode is enabled,
this menu is read-only.
Menu Type: Numeric Value.
Format: IP address in nnn.nnn.nnn.nnn (―dot decimal‖) format
SCPI Command: SYSTem:COMMunicate:LAN:ADDRess
<character data>
Main Pg 2 > System > I/O Config > Ethernet > Extensions > Subnet Mask
Description: Set the subnet mask for the Ethernet adapter. Note: If
DHCP/AutoIP mode is enabled, this menu is read-
only.
Menu Type: Numeric Value.
Format: Subnet mask in nnn.nnn.nnn.nnn (―dot decimal‖)
format
SCPI Command: SYSTem:COMMunicate:LAN:SMASk
<character data>
Main Pg 2 > System > I/O Config > Ethernet > Extensions > Def. Gateway
Description: Set the default gateway address for the Ethernet
adapter. Note: If DHCP/AutoIP mode is enabled, this menu is read-only.
Menu Type: Numeric Value.
Format: IP address in nnn.nnn.nnn.nnn (―dot decimal‖) format
SCPI Command: SYSTem:COMMunicate:LAN:DGATeway
<character data>
Fig. 4-49 Ethernet
Extensions Menu