Boonton 4540 Series RF Power Meter
Remote Operation
5-35
5.6.9 MEMory Subsystem
The MEMory group of commands is used to save and recall instrument operating configurations, and to edit and review user-
supplied frequency dependent offset (FDOF) tables for external devices in the signal path. Up to four configurations may be
saved, and two frequency dependent offset tables. Note, however that assigning a stored FDOF table to a particular
measurement channel is not a MEMory command; it is handled through the SENSe subsystem.
MEMory:SNSR:CFFAST?
Description: Return the sensor high bandwidth (FAST) frequency cal-factor table.
Syntax: MEMory:SNSR[1|2]:CFFAST?
Argument: None, query only.
Valid Modes: Any
MEMory:SNSR:CFSLOW?
Description: Return the sensor low bandwidth (SLOW) frequency cal-factor table.
Syntax: MEMory:SNSR[1|2]:CFSLOW?
Argument: None, query only.
Valid Modes: Any
MEMory:SNSR:CWRG?
Description: Return sensor AC cal data.
Syntax: MEMory:SNSR[1|2]:CWRG?
Argument: None, query only.
Valid Modes: Any
MEMory:SNSR:CWSH?
Description: Return sensor smart shaping table.
Syntax: MEMory:SNSR[1|2]:CWSH?
Argument: None, query only.
Valid Modes: Any